Fully Charged Voltage: 4,00 Fully Discharged Voltage: 3,00 Early Balancing Threshold: 3,95 Charge Finished Current: 0,20 Battery Capacity: 30,0 Number of Series Cells: 6 Allowed Disbalance: 15 Set SOC manually, %: 95 Over-Voltage Cutoff: 4,20 Under-Voltage Cutoff: 2,80 Discharge Overcurrent Cutoff: 30 Charge Overcurrent Cutoff: 20 Over-Heat Cutoff: 40 Low Temp. Charger Disable: 0 Automatic Recovery: 1 BMS Mode: Dual Port Single Port Switch Type: Internal FET Load Switch Type: Discharge FET Load Ignition: Disabled Load Precharge: Disabled Load Precharge Duration: 0.1 s Charger Type: Generic CC/CV Charger Switch Type: Charge FET Charger Detection: Internal Pulses Per Unit: 1 Distance Unit: Kilometers Speed Sensor Input: Disabled Broadcast: Disabled Protocol: ASCII Temperature Sensor Type: Dual 10K NTC Sensor Invert External Current Sensor Direction: 0 Disable Load/Charger Switch Diagnostics: 0